  technical data 1146 product description: the quik-spec? power module panel (pmp) is an all-in-one multi-elevator disconnect switch available in configurations to meet virtually any shutdown and disconnect requirement. quik-spec power module panel all-in-one elevator disconnect features and options: ? 400-800 amp bus mlo and/or main fused switch* ? 200ka rms short-circuit current rating ? feeder switches 30-200 amp, 600vac with class j clips 1 ? copper bus optional features: ? control power transformer with fuses and blocks ? fire safety interface relay ? key to test switch ? pilot light C on ? isolated neutral lug 2 ? mechanically interlocked auxiliary contact for hydraulic elevators with battery backup (5 amp 120vac rated) ? fire alarm voltage monitoring relay (to monitor shunt trip voltage) ? nema 3r enclosures available (consult factory) ? phase failure and undervoltage relay available (consult factory) ? for added safety, use the bussmann sami? fuse covers to improve maintenance personnel protection [osha 1910.335(a)(2)(ii)] 3 agency information: ? ul 67 enclosed and dead-front switches * contact bussmann for applications greater than 800 amps. 1 class j fuses not included. 2 oversized 200% rated neutral option available where required by excessive non-linear loads. 3 through 100a. effective july 2014 supersedes june 2008
2 technical data 1146 effective july 2014 power module pane l ratings (amps) (panelboard bus)c atalog numbe r 400 PMP-400 600 pmp-600 800 pmp-800 panel component s voltage/am p ratings component 1 (required ) control power transformer (cpt) std. 100v a 208v ac with pri & sec fuse (120v secondary) 240v ac 480v ac 600v ac component 2 (required ) fire safety interface relay (3pd t, 10 amp, 24vdc coil 120v) 120v ac coil component 3 (optional) key to test switch 120v ac component 4 (optional) pilot light ? ?on? red green whit e component 5 (optional) isolated neutral lug (full capacity) 2 30-60a 100a 200a component 6 (required ) mechanically interlocked auxiliary contact for 1 no & 1 nc hydraulic elevators with battery back-up (5 amp 120v ac rated) component 7 (optional) fire alarm voltage monitoring relays ingle-pole (t o monitor s hunt trip v oltage) 1 class j fuses not included. 2 oversized 200% rated neutral option available where required by excessive non-linear loads. 3 through 100a. maximum horsepower rating of switch feeder switch amp rating main fused switch amp rating voltage 30a 60a 100a 200a 400a 600a 800a 208v ac-3p 51 01 54 07 5 100 150 240v ac-3p 51 02 04 07 5 125 150 480v ac-3p 10 25 40 75 150 250 350 600v ac-3p 15 30 50 100 200 350 450 maximum horsepower rating of switch with class j fuses, medium-duty inr ush (nec ? code max 175%). recommended hp to calculate fuse and switch size. the above table can be used for estimating switch size for motor loads based upon the motor horsepower . size the switch so that the class j, time-delay fuses are used at a minimum of 150% of motor full-load amps or next size up. for general applications, excluding wound rotor and dc motors, nec ? 430.52 allows sizing at 175% of motor full-load amps or the next standard size per nec ? 240.6. note: in sizing the fuses, the motor fla, is per nec ? ta ble 430.250, not per nameplate information. inrush currents of motor s may vary, consult motor manufacturer data for correct sizing. on elevator applications, motor load plus auxiliary loads need to be considered. follow elevator manufacturer ?s recommendation for correct fuse sizing. standard shunt trip ratings: 30-100a, 200a & 400-800a voltag em ax inrus hm ax ontime 1 momentary inrus h 120v ac, 60hz 4 amps 1.5 cycles 140v a 1 will handle up to 447v a inrush. 0213 b u-sb08354 page 3 of 6 data sheet 1146 maximum horsepower rating of switch feeder switch amp rating main fused switch amp rating voltage 30a 60a 100a 200a 400a 600a 800a 208v ac-3p 51 01 54 07 5 100 150 240v ac-3p 51 02 04 07 5 125 150 480v ac-3p 10 25 40 75 150 250 350 600v ac-3p 15 30 50 100 200 350 450 maximum horsepower rating of switch with class j fuses, medium-duty inr ush (nec ? code max 175%). recommended hp to calculate fuse and switch size. the above table can be used for estimating switch size for motor loads based upon the motor horsepower . size the switch so that the class j, time-delay fuses are used at a minimum of 150% of motor full-load amps or next size up. for general applications, excluding wound rotor and dc motors, nec ? 430.52 allows sizing at 175% of motor full-load amps or the next standard size per nec ? 240.6. note: in sizing the fuses, the motor fla, is per nec ? ta ble 430.250, not per nameplate information. inrush currents of motor s may vary, consult motor manufacturer data for correct sizing. on elevator applications, motor load plus auxiliary loads need to be considered. follow elevator manufacturer ?s recommendation for correct fuse sizing. standard shunt trip ratings: 30-100a, 200a & 400-800a voltag em ax inrus hm ax ontime 1 momentary inrus h 120v ac, 60hz 4 amps 1.5 cycles 140v a 1 will handle up to 447v a inrush. 0213 b u-sb08354 page 3 of 6 data sheet 1146 power module pane l ratings (amps) (panelboard bus)c atalog numbe r 400 PMP-400 600 pmp-600 800 pmp-800 panel component s voltage/am p ratings component 1 (required ) control power transformer (cpt) std. 100v a 208v ac with pri & sec fuse (120v secondary) 240v ac 480v ac 600v ac component 2 (required ) fire safety interface relay (3pd t, 10 amp, 24vdc coil 120v) 120v ac coil component 3 (optional) key to test switch 120v ac component 4 (optional) pilot light ? ?on? red green whit e component 5 (optional) isolated neutral lug (full capacity) 2 30-60a 100a 200a component 6 (required ) mechanically interlocked auxiliary contact for 1 no & 1 nc hydraulic elevators with battery back-up (5 amp 120v ac rated) component 7 (optional) fire alarm voltage monitoring relays ingle-pole (t o monitor s hunt trip v oltage) 1 class j fuses not included. 2 oversized 200% rated neutral option available where required by excessive non-linear loads. 3 through 100a. quik-spec power module panel all-in-one elevator disconnect eaton www.eaton.com
3 technical data 1146 effective july 2014 module switch options, x dimensions and lug data switch conductors amp rating mounting ?x? unit sp er phase t erminal wire range 600v ? branch switch unit 1 30 horizontal 6x 1 #14 - 1/0 al or cu 30-30 horizontal 6x 1 #14 - 1/0 al or cu 60 horizontal 6x 1 #14 - 1/0 al or cu 60-60 horizontal 6x 1 #14 - 1/0 al or cu 100 horizontal 6x 1 #14 - 1/0 al or cu 100-100 horizontal 6x 1 #14 - 1/0 al or cu 200 horizontal 6x 1 #4 - 300 kcmil al or cu 200-200 horizontal 6x 1 #4 - 300 kcmil al or cu 600v - main fused switch 400 horizontal 1x 1 or 2( 1) 250 - 750kcmil (2) 3/0 - 250 kcmil al or cu 600 horizontal 3x 1 or 2( 1) #4 - 600kcmil (2) 1/0 - 250 kcmil al or cu 800 ve rtical 9x 1 or 2( 1) 250 - 750kcmil (2) 3/0 - 250 kcmil al or cu 1 may mix switch amps 30 to 200a: 30/60, 30/100, 30/200, etc. main lugs terminal data standard mechanical lugs main amp conductors min. wire bending space (inches) 2 rating per phase t erminal wire range ab c 400 13 /0 - 750 kcmil al or cu 14.00 10.625 7.00 23 /0 - 250 kcmil al or cu 600 2 #4 - 500 kcmil al or cu 14.00 10.625 7.00 800 4 #2 - 600kcmil al or cu 18.00 10.625 7.00 2 wire bending space can vary per local codes and standards requirements. top a b cc standard panel box dimension with available panel space dimensions (inches) amps h x w x d ?x? unit s 3 400 57 x 40 x 10.4 18x 600 73.5 x 44 x 10.4 30x 800 90 x 44 x 10.4 40x 3 where x units exceed panel space, use feed-through lugs and second enclosure. feed-through lugs amps ?x? space 400 3x 600 3x 800 7x wire bending space per nec ? ta ble 312.6(a) accessory control enclosur e ace6 x each ace will handle individual control power transformers and isolation relays for up to four switch units. x mlo incoming * - top or bottom accessory control enclosure (a ce)** 6 30a 30a 60a 60a 100a 100a 6 200a 200a feed-through lugs branch unit mounting space 40" * mlo standard, x-space does not affect brand x-space available. ** one a ce unit per four shunt trip module switches. * ** see table. *** 6 6 6 0213 b u-sb08354 page 2 of 6 data sheet 1146 quik-spec power module panel all-in-one elevator disconnect eaton www.eaton.com
4 technical data 1146 effective july 2014 ty pical control with wiring options for fire safety interface (option r1) legen d n.o.f .a. normally open fire alarm contacts supplied from the fire alarm system to initiate the shunt trip. shunt tr ip solenoid for remote trip of switch, which is activated by the closing of the fire alarm contacts or key test switch . option r1 fire safety interface relay that is operated at 120v ac from secondary of transformer . no additional power needed. cr control relay used to isolate the n.o.f .a. contacts from the duty of the shunt trip. fr fire alarm v oltage monitoring relay used to monitor presence of voltage in switch from a remote location (fire alarm control panel) . pl pilot light to visually indicate presence of voltage on outside of switch enclosure. cptc ontrol power tr ansformer used to step down line voltage to 120v ac to power shunt trip coil. sw aux. normally closed contact when switch is closed. opens as power switch opens. key te st key-to-t est switch used to operate shunt trip from the outside of switch enclosure. can be used for trouble-shooting and inspection. mechanically interlocked auxiliary contact ? contact used to disconnect secondary source of power .  te rminal block connection point .  pre-wired connection point . mechanically interlocked aux contact shunt trip option f1: relay terminal configuration v oltage monitoring note: contacts for fr are shown in de-energized postion. wiring diagram option a: battery backup terminal configuration mechanically interlocked auxiliary contact to connect the battery lowering for hydraulic elevator , connect to points nc and com. note: contacts for mechanically interlocked auxiliary contact are shown in the energized position. 1   age  of  ata heet 11 quik-spec power module panel all-in-one elevator disconnect eaton www.eaton.com
5 technical data 1146 effective july 2014 legen d n.o.f .a. normally open fire alarm contacts supplied from the fire alarm system to initiate the shunt trip. shunt tr ip solenoid for remote trip of switch, which is activated by the closing of the fire alarm contacts or key test switch . option r2 fire safety interface relay that is operated at 24vdc from fire alarm system. may require an additional power source to be needed. cr control relay used to isolate the n.o.f .a. contacts from the duty of the shunt trip. fr fire alarm v oltage monitoring relay used to monitor presence of voltage in switch from a remote location (i.e., fire alarm control panel) . pl pilot light to visually indicate presence of voltage on outside of switch enclosure. cpt control power tr ansformer used to step down line voltage to 120v ac to power shunt trip coil. sw aux. normally closed contact when switch is closed. opens as power switch opens . key te st key-to-t est switch used to operate shunt trip from the outside of switch enclosure. can be used for trouble-shooting and inspection. mechanically interlocked auxiliary contac t contact used to disconnect secondary source of power . te rminal block connection point. pre-wired connection point . wiring diagram option a: battery backup terminal configuration mechanically interlocked aux contact shunt trip vo ltage monitoring 24vdc source provided by fire alarm system mechanically interlocked auxiliary contact to connect the battery lowering for hydraulic elevator , connect to points nc and com. note: contacts for mechanically interlocked auxiliary contact are shown in the energized position. t ypical control with wiring options for fire safety interface (option r2) of quik-spec power module panel all-in-one elevator disconnect eaton www.eaton.com
technical data 1146 effective july 2014 the only controlled copy of this data sheet is the electronic read-only version located on the bussmann network drive. all other copies of this document are by definition uncontrolled. this bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. once a product has been selected, it should be tested by the user in all possible applications. eatons bussmann business 114 old state road ellisville, mo 63021 united states www.bussmann.com ? 2014 eaton all rights reserved publication no. 1146 - bu-sb14456 july 2014 eaton is a registered trademark. all other trademarks are property of their respective owners. quik-spec power module panel all-in-one elevator disconnect